Step 4.
Put WINDSHIELD DELUGE switch to off position (WP 0004).
Remove skid plate
grille (WP 0349).
Check hose from windshield deluge automatic drain valve to non-
operating nozzle for leaks, kinks, and damage.
a.
If hose is free from leaks, kinks, and damage, replace non-operating
windshield deluge nozzle (WP 0367).
b.
If hose is not free from leaks, kinks, or damage, replace
hose (WP 0320).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION