TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 937 of 1318

TM 9-2320-328-13&P-1
0084-3
DRAFT
0084
HWT0741
NOTE
Ensure system air pressure is at least 85 psi (586 kPa) during this procedure.
System air
pressure is required to activate valves.
Do not engage PUMP PTO during this procedure, except when performing complete
system checks.
Valve operations can be checked without water pump operation.
Valve operations can be checked by observing valve shaft rotation.
Valves are open when
tabs or yellow paint tabs are aligned with direction of fluid flow.
Step 3.
Push battery disconnect switch to on position (WP 0007). If system air pressure is
below 85 psi (586 kPa), start engine and allow system air pressure to build to at least
85 psi (586 kPa) (TM 9-2320-422-10).
Then shut off engine (TM 9-2320-422-10).
While an assistant puts cab or pump operator’s panel TANK TO PUMP switch to open
position (WP 0004), check if tank to pump valve operates.
If tank to pump valve does not operate, troubleshoot Tank-To-Pump Valve
Does Not Operate Properly (WP 0076).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top