TM 9-2320-328-13&P-1
0082-4
DRAFT
0082
Change 1
.
.
.
.
.
.
.
.
.
.
HWT0741
.
NOTE
Ensure system air pressure is at least 85 psi (586 kPa) during this procedure.
System air
pressure is required to activate valves.
Do not engage PUMP PTO during this procedure, except when performing complete
system checks.
Valve operations can be checked without water pump operation.
Valve operations can be checked by observing valve shaft rotation.
.
Step 4.
Push battery disconnect switch to on position (WP 0007).
If system air pressure is
below 85 psi (586 kPa), start engine and allow system air pressure to build to at least
85 psi (586 kPa) (TM 9-2320-422-10).
Then shut off engine (TM 9-2320-422-10).
While an assistant puts cab or pump operator’s panel TANK TO PUMP switch to OPEN
position (WP 0004), check if tank-to-pump valve operates.
.
If tank to pump valve does not operate, troubleshoot Tank-To-Pump Valve
Does Not Operate Properly (WP 0076).
.
.
.
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION