TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 922 of 1318

TM 9-2320-328-13&P-1
0081-16
DRAFT
0081
Change 1
..
HWT3079A
..
..
..
..
..
..
..
..
..
..
CAUTION
Both connector ends of water level probe adapter must be covered with heat
shrink tubing.
Failure to comply will allow moisture to enter connector ends and
not allow water level gauge to function properly.
..
Step 21.
Pull battery disconnect switch to off position (WP 0007).
With a test lead set, check for
continuity across wire 2740 (black) from passenger side body wire harness water level
probe connector, terminal A to a known good ground.
..
If there is continuity, go to Step 14.
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top