Step 13.
Pull battery disconnect switch to off position (WP 0007).
Disconnect main wire
harness pump operator’s panel 27-pin connector.
With a test lead set, check for
continuity across main wire harness wire 3853 (yellow) from main wire harness pump
operator’s panel 27-pin connector, terminal 25 to main wire harness passenger side
body wire harness connector, terminal 11.
..
a.
If there is continuity, repair wire 3853 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303)
..
b.
If there is no continuity, repair wire 3853 in main wire harness if
repairable TM 9-2320-325-14&P, or replace main wire
harness (WP 0292).
..