TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 909 of 1318

TM 9-2320-328-13&P-1
0081-3
DRAFT
0081
Change 1
..
Step 6.
Check if pump operator’s panel WATER level gauge F and 3/4 LEDs, and E and 1/4
LEDs flash alternately.
..
a.
If pump operator’s panel WATER level gauge F and 3/4 LEDs,
and E 1/4 LEDs flash alternately, replace pump operator’s panel
WATER level gauge (WP 0212).
..
b.
If pump operator’s panel WATER level gauge F and 3/4 LEDs,
and E and 1/4 LEDs do not flash alternately, fault corrected.
..
HWT3104
..
Step 7.
Pull battery disconnect switch to off position (WP 0007).
Open pump operator’s
panel (WP 0207).
Disconnect pump operator’s panel wire harness water level gauge
connector from pump operator’s panel WATER level gauge.
Disconnect pump
operator’s panel wire harness foam level gauge connector from pump operator’s panel
FOAM A gauge.
Connect pump operator’s panel wire harness water level gauge
connector to pump operator’s panel FOAM A level gauge.
Push battery disconnect
switch to on position (WP 0007).
Check if pump operator’s panel FOAM A level gauge
E and F LEDs flash alternately.
..
If pump operator’s panel FOAM A level gauge E and F LEDs do not flash
alternately, replace pump operator’s panel WATER Level
gauge (WP 0212).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top