TM 9-2320-328-13&P-1
0080-9
DRAFT
0080
HWT1119
Step 11.
Put pump operator’s panel PUMP COOLER switch to OFF position (WP 0004) and
release.
Put cab PUMP COOLER switch to on position (WP 0004) and release.
Check
if cab PUMP COOLER OPEN indicator illuminates.
If cab PUMP COOLER OPEN indicator does not illuminate, go to Step 14.
HWT0661A
Step 12.
Put cab PUMP COOLER switch to off position (WP 0004) and release.
Disconnect
main wire harness pump operator’s panel 27-pin wire harness connector.
With a test
lead set, check for 22 to 28 VDC between main wire harness wire 2834 (red) at main
wire harness pump operator’s panel 27-pin wire harness connector, terminal 7 and a
known good ground.
If 22 to 28 VDC are present, repair wire 2834 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator’s
panel wire harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION