TM 9-2320-328-13&P-1
0080-7
DRAFT
0080
HWT1056A
Step 8.
Put pump operator’s panel WATER TANK DRAIN switch to CLOSED position
(WP 0004).
Pull battery disconnect switch to off position (WP 0007).
Disconnect main
wire harness pump operator’s panel 27-pin wire harness connector.
With a test lead
set, check for continuity across main wire harness wire 4053 (brown) from main wire
harness pump operator’s panel 27-pin wire harness connector, terminal 14 to main wire
harness pump house wire harness connector, terminal 2.
a.
If there is continuity, repair wire 4053 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
b.
If there is no continuity, repair wire 4053 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0292).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION