HWT0669A
Step 13.
Remove skid plate grille (WP 0349).
Pull battery disconnect switch to off position
(WP 0004).
Disconnect main wire harness main 1 connector.
With a test lead set,
check for continuity across main wire harness wire 2834 (red) from main 1 connector,
terminal 4 to main wire harness pump operator’s panel 27-pin wire harness connector,
terminal 7.
If there is no continuity, repair wire 2834 in main wire harness if repairable
(TM 9-2320-325-14&P), or replace main wire harness (WP 0292).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION