TM 9-2320-328-13&P-1
0081-2
DRAFT
0081
Change 1
..
HWT3078
..
Step 1.
Push battery disconnect switch to on position (WP 0007).
Open pump operator’s
panel cover (WP 0010).
Check if cab and pump operator’s panel WATER level
gauges illuminate (WP 0004).
..
If cab and pump operator’s panel WATER level gauges do not illuminate,
troubleshoot Foam/Water Level Gauge(s) Does Not Illuminate (WP 0118).
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
NOTE
Water tank needs to be full to properly test pump operator’s panel WATER tank level
gauge for this step.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Step 2.
With water tank filled (WP 0015).
Check if pump operator’s panel WATER level gauge
reads full.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
If pump operator’s panel WATER level gauge does not read full, perform
Pump Operator’s Panel Water Level Gauge Calibration (WP 0212).
..
NOTE
Drain water tank to properly test pump operator’s panel WATER level gauge for this step.
..
Step 3.
With water tank drained (WP 0015), check if pump operator’s panel WATER level
gauge reads full.
..
If pump operator’s panel WATER level gauge reads full, go to Step 21.
..
Step 4.
Check if cab WATER level gauge 1/4 and 3/4 LEDs flash alternately.
..
If cab WATER level gauge 1/4 and 3/4 LEDs flash alternately, go to
Step 17.
..
Step 5.
Check if pump operator’s panel WATER level gauge E and F LEDs flash alternately.
..
If pump operator’s panel WATER level gauge E and F LEDs flash
alternately, go to Step 7.
..
MALFUNCTION
TEST OR INSPECTION