TM 9-2320-328-13&P-1
0081-10
DRAFT
0081
Change 1
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
HWT3221
..
WARNING
..
ICON 3
..
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry and tools may short across electrical circuits and cause damage to
equipment, or severe burns or electrical shock to personnel.
..
Step 15.
Disconnect main wire harness passenger side body wire harness connector.
With a
test lead set, check for continuity across wire 3851 (brown) from main wire harness
passenger side body wire harness connector, terminal 17 to pump operator’s panel
wire harness water level gauge connector, terminal 4.
..
If there is continuity, repair wire 3851 in lower passenger side body wire
harness if repairable (TM 9-2320-325-14&P), or replace passenger side
body wire harness (WP 0298).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION