Step 9.
Pull battery disconnect switch to off position (WP 0007).
With a test lead set, check for
continuity across wire 3895 from pump operator’s panel wire harness water level gauge
connector, terminal 2 to a known good ground.
a.
If there is continuity, replace pump operator’s panel water level
gauge (WP 0212).
b.
If there is no continuity, repair wire 3895 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
HWT2964
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 10.
Pull battery disconnect switch to off position (WP 0007).
Disconnect main wire harness
pump operator’s panel 27-pin connector.
Push battery disconnect switch to on
position (WP 0007).
With a test lead set, check for 22 to 28 VDC at wire 2342 from
main wire harness pump operator’s panel 27-pin connector to a known good ground.
If 22 to 28 VDC are present repair wire 2342 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator’s
panel wire harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION