TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1314 of 1390

TM 9-2320-328-13&P-2
0318-2
DRAFT
0318
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Pipes under 1.5 in. (38.1 mm) diameter, apply pipe sealant only.
Pipes 1.5 in. (38.1 mm) diameter or over, apply pipe sealant and teflon tape.
Leave first two or three threads exposed when applying pipe sealant and teflon tape.
2.
Apply four to five wraps of teflon tape (3) over threads of pipe (2) where pipe sealant (1) was applied.
3.
Apply pipe sealant (1) over threads of pipe (2) again, where teflon tape (3) was applied.
4.
Install pipe (2) in adapter (4). Screw pipe until completely tight and desired position is obtained.
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-422-10)
END OF TASK
END OF WORK PACKAGE
HWT0152
HWT0153


Back to Top