TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1316 of 1390

TM 9-2320-328-13&P-2
0319-2
DRAFT
0319
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Remove two elbows (3) and (4) from valve (8).
5.
Remove fitting (9) from valve (8).
6.
Remove nipple (10) and pipe (11) from valve (8).
7.
Remove nipple (10) from pipe (11).
8.
Remove fitting (6) from fitting (9).
END OF TASK
INSTALLATION
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
NOTE
Install cable ties as required.
1.
Apply sealing compound to threads of two fittings (6) and (9), elbows (3) and (4), and nipple (10).
2.
Install fitting (6) on fitting (9).
3.
Install fitting (9) on valve (8).
4.
Install nipple (10) on fitting (11).
5.
Install nipple (10) and pipe (11) on valve (8).
6.
Install two elbows (4) and (3) on valve (8).
HWT1907
WARNING
ICON 30, 44, 27


Back to Top