FIELD LEVEL MAINTENANCE
PUMP DRAIN VALVE REPLACEMENT
INITIAL SETUP:
REMOVAL
1.
Turn valve handle (1) clockwise to closed position.
NOTE
Cover is attached to valve handle with adhesive.
Note position of cover prior to removal to ensure proper installation.
Use care when removing cover.
2.
Pry cover (2) from valve handle (1).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT1855
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Adhesive, Spray (WP 0400, Item 5)
Tape, Teflon (WP 0400, Item 25)
Tags, Identification (WP 0400, Item 23)
Locknut (1)
References
WP 0391, Fig. 14
Equipment Conditions
Pump house panel H access door
opened (WP 0008)
Pump house panel P removed (WP 0339)


Back to Top