TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1341 of 1390

TM 9-2320-328-13&P-2
0322-1
DRAFT
0322
FIELD LEVEL MAINTENANCE
TANK-TO-PUMP VALVE REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Check valve and fitting must be removed in order to provide clearance when removing
tank-to-pump valve.
Tag and mark air lines prior to removal to ensure proper installation.
1.
Remove line (1) from elbow (2).
2.
Remove fitting (3) and check valve (4) from tee (5).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2835
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Compound, Sealing, Pipe Thread
(WP 0400, Item 11)
Tags, Identification (WP 0400, Item 23)
Personnel Required
MOS 63B Wheeled Vehicle Mechanic (2)
References
WP 0313
WP 0391, Fig. 20
Equipment Conditions
Air system drained (TM 9-2320-422-10)
Water tank drained (WP 0015)
Pump house panels K and G removed (WP 0339)