TM 9-2320-328-13&P-2
0324-1
DRAFT
0324
FIELD LEVEL MAINTENANCE
WINDSHIELD DELUGE AUTOMATIC DRAIN VALVE REPLACEMENT
INITIAL SETUP:
STRAINER REMOVAL
1.
Remove fitting (1), gasket (2), and strainer (3) from strainer body (4).
Discard gasket.
NOTE
•
Note position of fitting and reducer prior to removal to ensure proper installation.
•
Perform Steps (2) through (4) if fittings need to be removed.
2.
Remove line (5) from fitting (6).
3.
Remove fitting (6) from reducer (7).
4.
Remove reducer (7) from fitting (1).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2353
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Compound, Sealing, Pipe Thread
(WP 0400, Item 11)
Tags, Identification (WP 0400, Item 23)
Gasket (1)
Lockwasher (1)
Materials/Parts (continued)
Locknut
(1)
Lockwasher (1)
References
WP 0391, Fig. 94
Equipment Conditions
Skid plate grille removed (WP 0349)