TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1336 of 1390

TM 9-2320-328-13&P-2
0321-2
DRAFT
0321
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Stop on valve handle is positioned between 90 degree indent on valve.
Note position of valve handle on valve prior to removal to ensure proper installation.
3.
Remove locknut (3) and valve handle (1) from valve (4).
Discard locknut.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Remove two screws (5) and valve (4) from manual valve control mounting bracket (6).
5.
Loosen clamp (7) and remove hose (8) from elbow (9).
6.
Remove hose (10) from elbow (11).
HWT1636