TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 313 of 1390

TM 9-2320-328-13&P-2
0131.1-5
DRAFT
0131.1
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Amperage numerical values will vary, 0.340 A (amp) will be used as a reference only.
10. Press OK and Imin amperage numerical value will appear.
11. Press OK and amperage numerical value will be highlighted.
NOTE
Several adjustments may be necessary in order to correctly set static idle pressure.
Adjustments are made in increments of 0.005, i.e., from 0.340 A (amp) to 0.345 A (amp).
Adjustments are made by “tapping” up arrow, until value has increased by 0.005 A (amp).
12. Each tap up of arrow, will increase value 0.001 A (amp).
If value is increased by more than 0.005 A (amp), tap
down arrow to correct value.
HWT3464
HWT3465


Back to Top