7.
Install cover (4) on bumper turret mount (5) with six screws (3), 12 washers (2), and six locknuts (1).
END OF TASK
BUMPER TURRET NOZZLE SPEED ADJUSTMENT
NOTE
•
Reducing speed too much may cause erratic or incorrect shift pattern operation.
•
Nozzle speed control is adjusted by using a small screwdriver and turning two needle
valves clockwise or counterclockwise in increments of 1/8 of a turn.
•
Both needle valves must be turned in same direction and distance.
Failure to comply may
result in nozzle pattern sleeve drifting when pattern control rocker switch is released on
joystick.
•
To increase nozzle speed, turn both needle valves counterclockwise in increments of 1/8
of a turn.
•
To decrease nozzle speed, turn both needle valves clockwise in increments of 1/8 of a
turn.
•
Needle valve closest to nozzle discharge controls fog speed.
•
Needle valve closest to air cylinders controls straight stream speed.
•
Maintain air pressure in normal operating range (85 to 120 psi [586 to 827 kPa]) to ensure
accurate adjustment.