TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 329 of 1390

TM 9-2320-328-13&P-2
0134-5
DRAFT
0134
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
13. Remove four nuts (33), lockwashers (34), eight washers (35), four screws (36), and bracket (37) from four
brackets (13).
Discard lockwashers.
NOTE
Note position and orientation of brackets prior to removal to ensure proper installation.
14. Remove eight nuts (38), lockwashers (39), 16 washers (40), eight screws (41), and four brackets (13) from
hydraulic heat exchanger (19).
Discard lockwashers.
END OF TASK
INSTALLATION
NOTE
Install brackets on hydraulic heat exchanger as noted prior to removal.
1.
Install four brackets (13) on hydraulic heat exchanger (19) with eight screws (41), 16 washers (40), eight
lockwashers (39), and nuts (38).
2.
Install bracket (37) on four brackets (13) with four screws (36), eight washers (35), four lockwashers (34), and
nuts (33).
HWT2464


Back to Top