TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 323 of 1390

TM 9-2320-328-13&P-2
0133-1
DRAFT
0133
FIELD LEVEL MAINTENANCE
HYDRAULIC HEAT EXCHANGER FAN(S) SWITCH REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Disconnect pump house wire harness connector (1) from fan switch connector (2).
2.
Remove nut (3), lockwasher (4), two washers (5), cushion clip (6), screw (7), and fan switch connector (2)
from side shroud C (8) and rear shroud B (9).
Discard lockwasher.
NOTE
Place a suitable drain pan under fan switch.
3.
Remove fan switch (10) from hydraulic heat exchanger (11).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2769
Tools and Special Tools
Cap Set, Protective (WP 0398, Item 1)
Drain Pan (WP 0398, Item 4)
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Compound, Sealing, Pipe Thread
(WP 0400, Item 11)
Materials/Parts (continued)
Tags, Identification (WP 0400, Item 23)
Lockwasher (1)
References
WP 0391, Fig. 8
Equipment Conditions
Pump house panel K removed (WP 0339)


Back to Top