TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 328 of 1390

TM 9-2320-328-13&P-2
0134-4
DRAFT
0134
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Note position of tee prior to removing fitting to ensure proper installation.
8.
Remove fitting (23) and preformed packing (24) from hydraulic heat exchanger (19).
Discard preformed
packing.
9.
Remove tee (6) and preformed packing (25) from fitting (23).
Discard preformed packing.
10. Remove pressure relief valve (26) and preformed packing (27) from hydraulic heat exchanger (19).
Discard
preformed packing.
11. Remove plug (28) and preformed packing (29) from hydraulic heat exchanger (19).
Discard preformed
packing.
NOTE
Perform Step (12) if housing needs to be removed.
Note position of housing on hydraulic heat exchanger prior to removal to ensure proper
installation.
12. Remove eight screws (30), washers (31), and housing (32) from hydraulic heat exchanger (19).
HWT2628


Back to Top