TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 337 of 1390

TM 9-2320-328-13&P-2
0136-1
DRAFT
0136
FIELD LEVEL MAINTENANCE
HYDRAULIC HEAT EXCHANGER FAN(S) REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Both hydraulic heat exchanger fans are removed the same way.
Front hydraulic heat
exchanger fan shown.
Note position of hydraulic heat exchanger fans prior to removal to ensure proper
installation.
1.
Disconnect hydraulic heat exchanger fan connector (1) from pump house wire harness connector (2).
2.
Remove four screws (3), lockwashers (4), and hydraulic heat exchanger fan (5) from bracket (6).
Discard
lockwashers.
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT1933
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Lockwasher (4)
References
WP 0391, Fig. 8
Equipment Conditions
Hydraulic heat exchanger bottom shroud panel
removed (WP 0135)


Back to Top