TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 473 of 1390

TM 9-2320-328-13&P-2
0159-1
DRAFT
0159
FIELD LEVEL MAINTENANCE
PASSENGER SIDE AUXILIARY INLET DRAIN VALVE REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.
Turn valve handle (1) clockwise to closed position.
NOTE
Cover is attached to valve handle with adhesive.
Note position of cover prior to removal to ensure proper installation.
Use care when removing cover.
2.
Pry cover (2) from valve handle (1).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT1640
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Adhesive, Spray (WP 0400, Item 5)
Compound, Sealing, Pipe Thread
(WP 0400, Item 11)
Tags, Identification (WP 0400, Item 23)
Locknut (1)
References
WP 0391, Fig. 14
Equipment Conditions
Pump house panel H access door opened
(WP 0008)
Pump house panel P removed (WP 0339)


Back to Top