TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 487 of 1390

TM 9-2320-328-13&P-2
0162-3
DRAFT
0162
INSTALLATION
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
1.
Apply sealing compound to threads of elbow (9), and elbow (11).
NOTE
Install elbows as noted prior to removal.
2.
Install elbow (11) and elbow (9) on valve (4).
3.
Install hose (10) on elbow (11).
4.
Install hose (8) on elbow (9) and tighten clamp (7).
5.
Install valve (4) on manual valve control mounting bracket (6) with two screws (5).
NOTE
Install handle in the position as noted prior to removal.
6.
Install valve handle (1) on valve (4) with locknut (3).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-
-
-
-
WARNING
ICON 30, 44, 27