TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 489 of 1390

TM 9-2320-328-13&P-2
0163-1
DRAFT
0163
FIELD LEVEL MAINTENANCE
THERMAL RELIEF VALVE REPLACEMENT
INITIAL SETUP:
REMOVAL
1.
Disconnect thermal relief valve switch connector (1) from pump house wire harness connector (2).
2.
Remove drain line (3) from fitting (4).
3.
Remove thermal relief valve (5) from manifold (6) (WP 0318).
4.
Remove fitting (7) from thermal relief valve (5).
5.
Remove fitting (4) from thermal relief valve (5).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT1467
Tools and Special Tools
Standard Automotive Tool Set (SATS),
(WP 0398, Item 15)
• Wrench, Adjustable, 18”
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Compound, Sealing, Pipe Thread
(WP 0400, Item 11)
References
WP 0318
WP 0391, Fig. 13
Equipment Conditions
Pump house panel G removed (WP 0339)


Back to Top