TM-9-2320-328-13-P-3

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 3 OF 3

MARCH 2009

  TM-9-2320-328-13-P-3 - Page 195 of 844

TM 9-2320-328-13&P-3
0350-7
DRAFT
0350
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Remove screw (8), lockwasher (9), retainer (10), and twist lock (11) from pump house panel A access
door (1).
Discard lockwasher.
5.
Remove seal (12) from pump house panel A access door (1).
END OF TASK
PUMP HOUSE PANEL A ACCESS DOOR INSTALLATION
NOTE
Pump house panels G and K access doors are installed similarly.
1.
Install seal (12) on pump house panel A access door (1).
2.
Install twist lock (11) on pump house panel A access door (1), with retainer (10), lockwasher (9), and
screw (8).
3.
Install hinge (4) on pump house panel A access door (1) with two screws (7) and locknuts (6).
HWT1274


Back to Top