TM-9-2320-328-13-P-3

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 3 OF 3

MARCH 2009

  TM-9-2320-328-13-P-3 - Page 311 of 844

TM 9-2320-328-13&P-3
0374-1
DRAFT
0374
FIELD LEVEL MAINTENANCE
AIR LINES AND FITTINGS REPLACEMENT
INITIAL SETUP:
AIR HOSE FITTINGS
1.
Removing Air Line From Fitting.
CAUTION
Air lines may be removed directly from elbows and fittings, or may remain attached
to elbows and fittings and removed as an assembly.
If air lines are removed from
elbows and fittings, care must be taken not to damage air line.
If sealing surface of
air line is damaged air line must be repaired or replaced.
NOTE
Air line fitting shown, shows straight fitting located on shutoff control valve manifold.
Air lines attached to elbows and tees on air valves and shutoff control valve manifold are
replaced the same way.
a.
Remove air line (1) by pushing release button (2) towards body of fitting (3) and removing air line (1).
b.
Install air line (1) on fitting (3) until air line (1) bottoms in fitting (3).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT0203
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Compound, Sealing, Pipe Thread
(WP 0400, Item 11)
Tags, Identification (WP 0400, Item 23)
Ties, Cable, Plastic (WP 0400, Item 26)
References
WP 0389, Fig. 1
Equipment Conditions
Pump house panels A, D, E G, H, K, L removed
(if necessary) (WP 0339)
Air system drained (TM 9-2320-422-10)
Bumper turret cover removed (if required)
(WP 0378)


Back to Top