5.
Remove four screws (11), lockwashers (12), washers (13), and bumper turret control (10) from cover (3).
Discard lockwashers.
NOTE
Perform Step (6) if seal needs to be removed from bracket.
6.
Remove seal (14) from bracket (8).
NOTE
Perform Steps (7) through (12) if control knobs need to be removed.
Note position of control knobs on switches prior to removal to ensure proper installation.
7.
Loosen setscrew (15) and remove control knob (16) from switch (17).
HWT1510
HWT0160