TM-9-2320-328-13-P-3

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 3 OF 3

MARCH 2009

  TM-9-2320-328-13-P-3 - Page 336 of 844

TM 9-2320-328-13&P-3
0376.1-4
DRAFT
0376.1
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CAUTION
Rotor vane housing needs to be flipped 180 degrees in order for the steering pump
to operate correctly.
Failure to comply will not allow steering pump to operate
correctly.
3.
Remove rotor vane housing (3) and preformed packing (8) from steering pump body (4).
Discard preformed
packing.
4.
Lightly lubricate preformed packing (8) with clean oil, and install preformed packing (8) on steering pump
body (4).
5.
Flip rotor vane housing (3) 180 degrees and position rotor vane housing (3) on two alignment pins (9),
preformed packing (8), and steering pump body (4).
HWT3446


Back to Top