NOTE
Crane control valves have variable speed capability. Moving a lever
slightly will cause slow movement of the crane function. Moving the
lever to its full travel will cause the crane function to move faster.
y.
Check each of the five switch levers on remote-control unit (3) for proper response
and function (refer to HIAB crane front remote station and remote-control system
controls and indicators (WP 0027) for more information).
z.
Push remote-control ON/OFF power switch (8) to OFF position until ready to use
crane.
WARNING
Do not exceed crane load lift limits. In manual operation, overload
protection device is not functional and safe crane limits could be ex-
ceeded. Failure to comply may result in injury or death to personnel.
WARNING
Pilot-operated overcenter valves which are active during manual valve
operation may allow the operator to lift a load which exceeds limits,
but when control lever is released, load will automatically lower.
WARNING
Before lifting load, check all rigging (lines, slings, chains, pallets, etc.)
for correct attachment to load and rated capacity. Failure to check
these items may cause load to fall, resulting in injury to personnel.
CAUTION
Continuous crane operation for extended periods of time may cause
hydraulic oil to overheat. Extended periods of high idle with PTO pump
TM 9-2320-344-10
0036
0036-37