TM 9-2320-361-10
2-26. OPERATION OF FUEL TANK TRUCK (Contd)
(10)
When tank is filled, remove dispenser hose (1) from filler hole (3).
(11)
Install filler cover (5) on filler hole (3).
(12)
Close manhole cover (7) and install padlock (4).
(13)
Install nozzle (2) on dispenser hose (1).
(14)
Remove ground wire (17) from ground rod (16) and retract on cable reel (18).
(15)
Retract ground wire (17) on cable reel (18) and stow on fuel tank truck.
WARNING
Ž Fuel tank sections should only be top loaded when bottom loading
is not possible. Top loading causes static electricity which may
cause fire, resulting in injury or death to personnel.
Ž Keep at least 25 ft (7.6 m) between fuel tank vehicles during
fueling operations to avoid congestion. Failure to do so may result
in injury or death to personnel.
c. Suction Filling the Tank Sections or Transferring Fuel from One
Source to Another Using Vehicle Pump.
(1)
Park truck at least 25 ft (7.6 m) from fuel supply.
(2)
Attach ground wire (17) to suitable ground (task a.1).
(3)
Remove gravity delivery line gate valve dust cover (14) from gravity
delivery valve adapter (12).
(4)
Open hose compartment doors (10) and remove hoses (13) as necessary.
(5)
Attach hose (13) to gravity delivery valve adapter (12).
(6)
Turn meter drain knob (9), manual drain valve knob (11), and delivery
pump draincock (15) right to closed position.