TM-9-2320-361-10

2-1/2-TON, 6x6, M44A2 SERIES TRUCKS (MULTIFUEL)

OPERATOR'S MANUAL

DECEMBER 1988

  TM-9-2320-361-10 - Page 194 of 392

TM 9-2320-361-10
2-28. OPERATION OF SHOP VAN AND INSTRUMENT
REPAIR SHOP TRUCKS (Contd)
(2)
Remove cable connector dust cover (16).
(3)
Install cable connector (15) from outside 115-volt AC power source in
receptacle (14).
(4)
When van is to be moved, remove connector (15) and install dust
cover (16).
c. Operating Exhaust Blower.
(1)
To operate from 115-volt AC source:
(a)
Place power switch (18) in up position.
(b)
Place heater circuit breaker (17) in UP position.
(c)
Place converter selector switch (20) in 115-volt position. Red light (19)
will light.
(d)
Place exhaust blower switch (21) in HIGH or LOW position.
(2)
To operate from 24-volt DC source:
(a)
Place power switch ( 18) in down position.
(b)
Place converter selector switch (20) in 24-volt position.
(c)
Place exhaust blower switch (21) in HIGH or LOW position.
2-133