TM 9-2320-361-10
2-28. OPERATION OF SHOP VAN AND INSTRUMENT
REPAIR SHOP TRUCKS (Contd)
(4)
Operating 24-volt dome lights under blackout conditions.
(a)
Place power switch (3) in down position.
(b)
Place dome light toggle switch (4) in ON position.
(c)
Place blackout dome light toggle switch (5) in BLACKOUT position.
(d)
Open and close rear doors as necessary, to check operation of blackout
lights.
e. Supplying 115-Volt Power to Molding Receptacles.
(1)
Place power switch (3) in up position.
(2)
Place right side power circuit breaker (8) in ON position to supply power
to right side molding receptacles (7).
(3)
Placee left side power circuit breaker (9) in ON position to supply power to
left side molding receptacles (6).
2-135