2-51. OPERATION OF CARGO BODY ARCTIC KIT (Contd)
(9)
Adjust hot air flow with diverter control lever (1)
NOTE
Blower motor will continue to run for one to three minutes
after RUN-OFF-START switch is turned to OFF position. Red
indicator light will remain on until fuel in heater burns away
and heater cools.
(10)
After heater operation, turn RUN-OFF-START switch (3) to OFF position.
(11)
Close fuel tank shutoff cock (4)
by turning clockwise.
(12)
Close diverter by turning diverter
cent 01 lever (1) counterclockwise.
NOTE
Step (13) applies to vehicles
equipped with swingfire heater
only.
(13)
After heater operation, remove
lockpin (5) and open door (6). Remove
and shut down swingfire heater as
necessary. Refer to para. 2-59. Close door
(6) and install lockpin (5).