TM 9-2320-361-10
2-59. OPERATION OF SWINGFIRE HEATER (Contd)
(7)
Raise power receptacle cover (1) and install one end of starter cable (2) in
power receptacle (3). Install other end of starter cable (2) in starter cable
receptacle (6).
(8)
Squeeze ignition switch (5) against pump lever (4) and hold there one
minute for every 10°F below 0°F, then release.
NOTE
It maybe necessary to loosen wingnut and open cover slightly
so pulsating sounds can be heard more clearly.
(9)
Move pump lever (4) forward and backward three or four times, then turn
fuel regulator knob (8) one to one-and-a-half turns counterclockwise. Continue
moving hand lever (4) and adjust fuel regulator knob (8) until pulsating sounds
come to equal intervals.
(10)
When pulsating sounds come to equal intervals, stop moving pump lever
(4).
(11)
Let swingfire heater (9) run three
to five minutes. Adjust fuel regulator
knob (8) if pulsations are not at equal
intervals.
(12)
Close cover (7) if opened and
tighten wingnut (12) by turning
clockwise.
(13)
Remove starter cable (2) from
starter cable receptacle (6) and power
receptacle (3). Close power receptacle
cover (1).
(14)
Install swingfire heater (9) in mixing pipe (refer to c. of this para.),
turboheater (refer to d. of this para.), or water jacket (refer to e. of this para.) as
necessary.
2-216