TM9-2320-361-10
2-59. OPERATION OF SWINGFIRE HEATER (Contd)
(5)
Allows swingfire heater (1) to run
until temperature gage reads 190°F.
(6)
When temperature gage reads
19°F, loosen wingnut (2) by turning
counterclockwise and remove swingfire
heater (1). Start engine. Refer to
para. 2-15.
(7)
Install cap (4) on end of water
jacket (3).
(8)
Install swingfire heater (1) in
mixing pipe or turboheater, or stow, as
necessary (refer to f. of this para.)
f. Stowage of Swingfire Heater and
Mixing Pipe.
(1) General.
Swingfire heater and
mixing pipe are stowed under companion
seat.
(2)
Shut off swingfire heater (1)
(refer to b. of this para.).
(3)
Position swingfire heater (1) on
stowage brackets (7). Place strap (5) over
swingtire heater (1) and install hook (6)
on stowage bracket (7).
(4)
Position mixing pipe (11) on
stowage brackets (9). Place straps (10)
over mixing pipe (11) and install latches
(8) on stowage brackets (9).
2-220