12-31. GALLON METER REPLACEMENT (M49A2C)
This task covers:
a. Removal
b. Installation
INITIAL SETUP:
APPLICABLE MODELS
EQUIPMENT CONDITION
M49A2C
Parking brake set (TM 9-2320-361-10).
MATERlALS/PARTS
Meter outlet tube removed (para. 12-37).
Globe valve removed (para. 12-27).
Three lockwashers
Meter-to-filter tube removed (para. 12-30).
REFERENCES (TM)
TM 9-2320-361-10
TM 9-2320-361-20P
1. Remove three screws (4), lockwashers (5), and gallon meter (1) from shelf (6). Discard lock-
washers (5).
2. Remove pipe (3) from elbow (2) and elbow (2) from gallon meter (1).
1. Install elbow (2) on gallon meter (1) and pipe (3) on elbow (2).
2. Install gallon meter (1) on shelf (6) with three screws (4) and new lockwashers (5).
FOLLOW-ON TASKS:
Install meter-to-filter tube (para. 12-37).
Install globe valve (para. 12-27).
Install meter outlet tube (para. 12-30).