TM 9-2320-361-24-1
0013 00
0013 00-14
LIGHTING AND WIPER SYSTEM TROUBLESHOOTING (Contd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. DIRECTIONAL
SIGNAL
INOPERATIVE
(Contd)
Test 4. Test continuity of front
composite light wiring harness.
1. Disconnect lead 461 from front
composite light.
2. Disconnect cable connector at
turn signal switch.
3. Set multimeter to RX 1 scale.
4. Touch multimeter negative
lead to pin B at cable
connector.
5. Touch multimeter positive lead
to contact end of 461 at front
composite light.
Test 5. Test continuity of turn signal
switch.
1. Disconnect cable connector at
turn signal switch.
2. Place turn signal switch in left
position.
3. Touch multimeter negative
lead to pin G of turn signal
switch.
4. Touch multimeter positive lead
to pin B 461 (front left) and pin
C 22-461 (left rear) of turn
signal switch.
5. Place turn signal lever in right
position.
6. Touch multimeter positive lead
to pin A 460 (right front) and
pin E (right rear) at turn
signal switch.
7. Touch multimeter positive lead
to pin F at turn signal switch.
1. If continuity is not present, repair or
replace lead 461 (WP 0090 00).
2. Perform test 4 again. If lamp fails to
flash, go to test 5.
If continuity is not present, replace
turn signal switch (WP 0102 00).
If continuity is not present, replace
turn signal switch (WP 0102 00).
If continuity is not present, replace
turn signal switch (WP 0102 00).
Table 3. Directional Signal Systems Troubleshooting Procedures (Contd).