TM 9-2320-361-24-2
0313 00
0313 00-1/2 blank
FIELD MAINTENANCE INSTRUCTIONS
2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL)
115-VOLT WIRING HARNESS REPLACEMENT
REMOVAL AND INSTALLATION
INITIAL SETUP:
Applicable Models
M185A3, M109A3
Tools and Special Tools
General mechanic’s tool kit
(item 116, WP 0469 00)
Electrical tool kit (item 114, WP 0469 00)
Materials/Parts
Electrical tape (item 43, WP 0468 00)
Equipment Condition
Parking brake set and wheels chocked
(TM 9-2320-361-10).
Battery ground cable disconnected
(WP 0126 00).
115-Volt receptacles removed (WP 0311 00).
NOTE
Both 115-volt receptacle wiring harnesses are replaced the same way.
This procedure covers one harness.
REMOVAL
NOTE
Prior to removal, tag lead wires, cables, and terminals for installation.
1.
Remove electrical tape from connectors (4).
2.
Cut receptacle wiring harness (3) from main wiring harness (1) at connectors (4).
3.
Remove receptacle wiring harness (3) from receptacle strip (2).
INSTALLATION
1.
Place receptacle wiring harness (3) in receptacle strip (2).
2.
Connect receptacle wiring harness (3) to main wiring harness (1) at connectors (4).
3.
Wrap connectors (4) with electrical tape.
4.
Install 115-volt receptacles (WP 0311 00).
5.
Connect battery ground cable (WP 0126 00).
6.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
END OF WORK PACKAGE
1
2
4
3
4