TM-9-2320-361-24-2

2-1/2 TON, 6X6, M44A2 SERIES TRUCKS

TECHNICAL MANUAL; FIELD AND SUSTAINMENT MAINTENANCE PART 2 OF 2

AUGUST 2006

  TM-9-2320-361-24-2 - Page 650 of 1144

TM 9-2320-361-24-2
0376 00
0376 00-4
PRIMARY HEATER FUEL LINES REPLACEMENT (Contd)
PUMP OUTLET-TO-ADAPTER TUBE REMOVAL
1.
Remove screw (4) and clamp (5) from fuel line (6) and van body (1).
2.
Remove fuel line (6) from elbows (3) and (7).
3.
Remove elbow (3) from adapter (2) and elbow (7) from pump outlet (8).
PUMP OUTLET-TO-ADAPTER TUBE INSTALLATION
NOTE
Wrap male pipe threads with antiseize tape prior to
installation.
1.
Install elbow (3) on adapter (2) and elbow (7) on pump outlet (8).
2.
Install fuel line (6) on elbows (3) and (7).
3.
Install clamp (5) and fuel line (6) on van body (1) with screw (4).
4.
Install pump cover (WP 0374 00).
5.
Connect battery ground cable (WP 0126 00).
6.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
1
2
3
4
6
6
7
8
5
6
7
~


Back to Top