KNOWN INFO
TEST OPTIONS
REASON FOR QUESTION
1.
YES
NO
START
Operational Test
e110.
M1079 110 VAC OUTLET J231 DOES NOT OPERATE
TM 9-2320-365-20-2
2-1194
Change 1
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10).
AC power connected (TM 9-2320-365-10).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Personnel Required
(2)
References
TM 9-4910-571-12&P
This question eliminates
possible problems and
determines where
troubleshooting continues.
Does 110 VAC outlet J234
operate?
Go to step 5 of this fault.
POSSIBLE PROBLEMS
110 VAC outlets J230,
J232, J233, and J235 OK.
Faulty circuit breaker CB7.
Faulty wire 701B.
Faulty wire 702B.
Faulty relay K35.
Faulty 110 VAC receptacle
J231.
Faulty wire 1499C.
Faulty wire 3085M.
Faulty wire 3085AB.