TM-9-2320-365-20-2

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-2 - Page 143 of 1432

Change 1
2-1197
TM 9-2320-365-20-2
CONTINUITY TEST
(1)
Disconnect AC power (TM 9-2320-
365-10).
(2)
Remove screw and cover from 110 VAC
outlet J231.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter
to supply pole of 110 VAC receptacle
J231.
(5)
Connect negative (-) probe of multimeter
to supply socket of 110 VAC receptacle
J231 and note reading on multimeter.
(6)
Connect positive (+) probe of multimeter
to neutral pole of 110 VAC receptacle
J231.
(7)
Connect negative (-) probe of multimeter
to neutral socket of 110 VAC receptacle
J231 and note reading on multimeter.
(8)
Connect positive (+) probe of multimeter
to ground pole of 110 VAC receptacle
J231.
(9)
Connect negative (-) probe of multimeter
to ground socket of 110 VAC receptacle
J231 and note reading on multimeter.
(10)
If continuity is not present in steps (5), (7),
and (9), replace 110 VAC receptacle J231
(para 16-53).


Back to Top