2-1206
Change 1
e110.
M1079 110 VAC OUTLET J231 DOES NOT OPERATE (CONT)
7.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
Continuity Test or
STE/ICE-R Test
#91
REASON FOR QUESTION
Replace relay K35
(para 16-62).
110 VAC outlets J230,
J232, J233, and J235 OK.
110 VAC outlet J234 does
not operate.
Circuit breaker CB7 OK.
Wire 701B OK.
Faulty wire 702B.
Faulty relay K35.
Is continuity present on
wire 702B from K35 relay
base terminal 5 to 110 VAC
receptacle J231 supply
pole?
If continuity is not present,
wire 702B is faulty. If
continuity is present, relay
K35 is faulty.
YES
Repair or replace wire 702B
(para 2-40).