e108.
M1079 110 VAC OUTLET J232 DOES NOT OPERATE IN NORMAL MODE (CONT)
TM 9-2320-365-20-2
2-1188
Change 1
7.
KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE-R Test
#91
REASON FOR QUESTION
POSSIBLE PROBLEMS
Fluorescent lights OK.
Circuit breaker CB5 OK.
Wire 701A OK.
Faulty wire 702A.
Faulty relay K35.
Is continuity present on
wire 702A from K35 relay
base terminal 4 to supply
pole of 110 VAC receptacle
J232?
If continuity is not present,
wire 702A is faulty. If
continuity is present, relay
K35 is faulty.
Repair or replace wire 702A
(para 2-40).
YES
Replace relay K35
(para 16-62).