M1079 110 VAC OUTLET J232 DOES NOT OPERATE IN NORMAL MODE (CONT)
TM 9-2320-365-20-2
2-1180
Change 1
3.
KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE-R Test
#91
REASON FOR QUESTION
Fluorescent lights OK.
110 VAC outlet J233 OK.
110 VAC receptacle J232 OK.
POSSIBLE PROBLEMS
Faulty wire 1499B.
Faulty wire 3085K.
Faulty wire 3085AA.
Is continuity present on
wire 1499B from 110/208
VAC POWER DISTRIBUTION
PANEL to 110 VAC
receptacle J232?
If continuity is not present,
wire 1499B is faulty.
NO
Repair or replace wire 1499B
(para 2-40).
YES