TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
2-1315
2-1315
2-1315
2-1315
2-1315
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
circuit breaker CB11 wire 49.
(3)
Connect negative (-) probe of multimeter to
J237 24 vdc positive (+) binding post and note
reading on multimeter.
(4)
If continuity is not present, repair or replace
wire 49 (para 2-40).
(5)
Close cover on relay box assembly.
(6)
Tighten screw in cover.