TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
2-1313
2-1313
2-1313
2-1313
2-1313
CONTINUITY TEST
(1)
Push in circuit breaker CB11.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
one end of circuit breaker CB11.
(4)
Connect negative (-) probe of multimeter to
other end of circuit breaker CB11 and note
reading on multimeter.
(5)
If continuity is not present, replace circuit
breaker CB11 (para 16-61).