TM-9-2320-365-20-3

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 3 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-3 - Page 195 of 1268

TM 9-2320-365-20-3
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing.
Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to
comply
may
result
in
injury
to
personnel.
(1) Apply antiseize compound to threads of ether sensor (1).
(2) Install ether sensor (1) in coolant bypass tube (2).
NOTE
Both coolant hoses are assembled the same
way. Only one shown.
(3) Loosen two screws (3) in clamps (4) and clamps (5) as
far as possible without disengaging screws from D-nuts
(6).
(4) Unhook clamp tabs (7) from tab windows (8).
6-37


Back to Top